Products
- "Five do not" make you better use of high and low temperature test chamber
- Ozone aging test chamber development prospects are very broad
- HMDS pretreatment system has five advantages introduced
- Alcohol on the vacuum oven will explode in addition to water?
- Six steps to easily get the vacuum oven installation work
- Five knowledge points that need to be known when using the oven
- What is the better choice for vacuum oven?
- Trueping Technology won the TSMC Nanjing factory bulk purchase orders
Location: 首页 » Products » Anti - oxidation equipment » Dust free nitrogen cabinet
Anti - oxidation equipment
Dust free nitrogen cabinet
Applications:
Solve the wetness, oxidation and destruction of wafers (Wafer) by other gases (ex Amorian gas)
Solve the problem of moisture and oxidation of the probe card
Solve the problem of moisture in the Photomask – yellow light area
Packaged gold wire (Bonding wire)
Solve the problem of liquid crystal moisture
Solve the problem of moisture on the circuit board
- Product Details
- Features
- Application Areas
Dust free nitrogen cabinet
Applications:
Solve the wetness, oxidation and destruction of wafers (Wafer) by other gases (ex Amorian gas)
Solve the problem of moisture and oxidation of the probe card
Solve the problem of moisture in the Photomask – yellow light area
Packaged gold wire (Bonding wire)
Solve the problem of liquid crystal moisture
Solve the problem of moisture on the circuit board
1、Nitrogen monitoring system:
1.1、2.3” LED Large screen digital display humidity/temperature.
1.2 、Humidity display value of 0.1%-99.9%RH,temperature display value of 0.1℃-60.0℃.
1.3 、Temperature and humidity collection adopts high-precision sensors, long-distance transmission without error.
1.4 、Humidity control:
1.4.1 It uses the humidity setting value to control the inflow of nitrogen. When the humidity setting value is reached, the intake air is stopped to save nitrogen consumption.
1.4.2 Humidity can be adjusted from 1% to 60% RH.
1.5、Temperature and humidity recording function:
1.5.1 Built-in memory can store temperature / humidity, collection time 1~240 minutes can be set by yourself.
1.5.2 It can be downloaded to the computer for reading using RS232 connection.
1.5.3 Design of product tube record format helps internal record tracking and supports database file formats.
1.6、Humidity alarm system:
1.6.1 The humidity value and condition of the start alarm can be set, and the buzzer (90 dB) and the flashing warning function are provided. 1.6.2 Additional layered warning lights can be selected.
1.7、Temperature and humidity offset correction function: built-in calibration function to ensure display accuracy.
2.Ultra-efficient filtration system:
2.1 EBM electronic EC motor controls the special FFU of the dust-free chamber.
2.2 Mirror stainless steel structure.
2.3 Special diversion air duct design and the average wind pressure can effectively provide air volume and reduce noise.
2.4 Circuit board control module provides safety protection device, abnormal operation indicator and dry contact output control.
2.5 The stepless air volume governor can adjust the air volume arbitrarily.
2.6 Ultra-efficient filter ULPA, 0.12μm, 99.9995% or more filtration effect.
2.7 Power Specifications: Single-phase 220V 50Hz 0.95A, maximum output power 150W.
3.Cabinet specification, size and equipment:
3.1 Left and right double opening, 3mm tempered glass, 1mm thick stainless steel plate, the door handles all adopt pressed handles to avoid dust particles generated by the friction between the switch door and the inner cabinet.
3.2 The cabinet is sealed with high adsorption force. The magnetic strip is sealed with the cabinet. The floor mats are used to support the wheels and adjust the height and floor mats.
3.3 Each piece can carry more than 80kg, and the cabinet is equipped with high-load wheels.
3.4 Upper airtight cover for easy maintenance and repair of FFU.
3.5 Return air circulation design, unidirectional nitrogen circulation does not produce turbulence.
3.6 The airtight door design on the back makes it easy to clean and maintain.
4、Products are strictly controlled and tested for 24 hours by quality certification manufacturers before they leave factory.
Model | size: width*height*depth(MM) | Practical L | Dehumidification | layer | Notes |
CM8160 | W1250*H2050*D850 | 1200 | 1900 | 5 | Optional static elimination system |
CM1001 | W1250*H2500*D850 | 1500 | 2200 |
Dust free nitrogen cabinet
Applications:
Solve the wetness, oxidation and destruction of wafers (Wafer) by other gases (ex Amorian gas)
Solve the problem of moisture and oxidation of the probe card
Solve the problem of moisture in the Photomask – yellow light area
Packaged gold wire (Bonding wire)
Solve the problem of liquid crystal moisture
Solve the problem of moisture on the circuit board
Applications:
Solve the wetness, oxidation and destruction of wafers (Wafer) by other gases (ex Amorian gas)
Solve the problem of moisture and oxidation of the probe card
Solve the problem of moisture in the Photomask – yellow light area
Packaged gold wire (Bonding wire)
Solve the problem of liquid crystal moisture
Solve the problem of moisture on the circuit board
Related Products